Aerial Bunched Cables



Aerial Bunched Cables   Next >>

Product Code : KM-05

Product Specification

Aerial Bunched Cables

Aerial Bunched Cable is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system. It is being designed, manufactured & tested as per IS: 14255 & other international specifications. It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost. This system is ideal for rural distribution and it is especially perfect for installation in difficult terrains such as hilly areas, forest areas, coastal areas etc. ABC is also considered to be ideal for power distribution in congested urban areas with narrow lanes and by-lanes. In developing urban complex, ABC is the first choice because of its flexibility

Applications

  • Aerial Bunched Cables are suitable for the following functions mentioned as under:
  • As replacement of bare line in rural areas, in woods, other localities & narrow street where space is limited
  • As replacement of bare line where reliability of supply is of prime importance
  • As replacement of bare lines where high degree of stability of supply voltage is of importance
  • In hilly terrains where cost of erection of overhead lines of under ground cable becomes very high
  • As reinforcement of existing system without increasing voltage
  • For temporary supplies

Advantages

  • Aerial Bunched Cables Lines have very high reliability in maintaining services because power and neutral conductors are insulated with the best dielectric. The benefits of using this line are:
  • Less fault rage on account of good protection against line and ground fault by high winds or falling trees or bird especially in hilly areas & forests as encountered in rural distribution networks.
  • High insulation resistance to earth in all seasons and polluted atmospheres. Negligible leakage currents and low losses.
  • Multiple circuits of power and telephone cables could be strung in the same set of poles or any other supports like walls etc.
  • Better adaptability to "in concurrently with existing over-head bare conductor system without any interference.
  • High capacitance and low inductance leading to low impedance of lines.
  • Lower voltage drop, higher current carrying capacitates, ie. better voltage regulation.
  • Total lines costs are reduced.
  • Maintenance is very easy. Very difficult to tap ABC cables, thus reducing theft, which leads to lower distribution losses.
LT AERIAL BUNCHED CABLES AS PER IS: 14255-1995

Phase Conductor Aluminum
Street Lighting Conductor Aluminium
Messenger Conductor Aluminium Alloy
Nom. Area
Max. D.C Conductor Resistance At 20 Deg. C
Nom. Thickness Of Insulation XLPE/PF
Nom. Area
Max. D.C Conductor Resistance At 20 Deg. C
Nom. Thickness Of Insulation XLPE/PE
Nom. Area
Max. D.C Conductor Resistance At 20 Deg. C
Min. Breaking Load
Sqmm
Ohm/Km
mm
Sqmm
Ohm/Km
mm
Sqmm
Ohm/Km
KN
16
1.91
1.2
16
1.91
1.2
25
1.38
7
25
1.2
1.2
16
1.91
1.2
25
1.38
7
35
0.868
1.2
16
1.91
1.2
25
1.38
7
50
0.641
1.5
16
1.91
1.2
35
0.986
9.8
70
0.443
1.5
16
1.91
1.2
50
0.689
14
95
0.32
1.5
16
1.91
1.2
70
0.492
19.7


COMPOSITION AND DESIGNATION OF LT AERIAL BUNCHED CABLES AS PER RED SPECIFICATION NO. 32



Designation
Complete Bunched Cables
Approx. Overall Dia.
Approx. Total Mass
 
mm
Kg/Km
3X16+25
19
250
3X16+16+25
19
310
3X25+25
22
330
3X25+16+25
22
390
3X35+25
24
430
3X35+16+25
24
490
3X50+35
32
580
3X50+16+35
32
640



LT AERIAL BUNDLED CONDUCTOR (ABC) POLYMERIC INSULATED AS PER BS: 7870 (PART-5) 1999



Nominal Cross Sectional Area of Conductor
Max. D.C Resistance At 20 Deg. C Of XLPE Mix Average Thickness Conductor Ultimate Tensile Strength of Insulation
25
1.200
1.3
4.1
35
0.868
1.3
5.6
50
0.641
1.5
7.6
70
0.443
1.5
11.0
95
0.320
1.7
15.3
120
0.253
1.7
19.4

CHARACTERISTICS OF CONDUCTORS AND CORES FOR LT AERIAL BUNCHED CABLES ASPER NFC 33-2099

Designation
Conductor
Average Thickness of Insulating Sheath Specified Min.
Core
Type
Nominal Sectional Area
No. of Strands
Max. Linear Resistance At 20 Deg. C
Min. Conductor Dia. Min.
Breaking Strength Max.
Breaking Strength Max.

Max.


Sqmm

Ohm/Km
mm
daN
daN
mm
mm
mm
PHASE OR NEUTRAL NON RETURN
16
7
1.91
4.7
190
290
1.2
7
7.9











25
7
12
6
300
450
14
8.7
9.6

35
7
0.641
8.2
600
900
1.6
11.3
12.3

50
7
0.641
8.2
600
900
1.6
11.3
12.3

70
12
0.443
9.8
840
1260
1.8
13.3
14.3
NEUTRAL RETURN
54.6
7
0.63
9.2
1660
-
1.6
12.3
13


COMPOSITION AND DESIGNATIN OF HT AERIAL BUNCHED CABLE AS PER REC SPECIFICATION NO. 64

Designation
Complete Bunched Cables
Approx. Overall Dia.
Approx. Total Mass
Mm
Kg/Km
6.35/11 KV 3X35+70
53
1450
6.35/11 KV 3X70+70
59
1900
Other Products in 'Aerial Bunched Cables' category
Screened Shielded Instrumentation Cable
Screened Shielded Instrumentation Cable
 
<< Back



PTFE / Teflon Wires
PTFE / Teflon Wires
Thermocouple Cables
Thermocouple Cables
Electrical Wires
Electrical Wires
Twisted Pair Lan Cable
Twisted Pair Lan Cable
Twisted Pair Cable
Twisted Pair Cable
Aerial Bunched Cables
Aerial Bunched Cables
Screened Shielded Instrumentation Cable
Screened Shielded Instrumentation Cable
Silicon EPR Rubber Insulated Cables
Silicon EPR Rubber Insulated Cables
PVC Insulated Battery Cables
PVC Insulated Battery Cables
PVC Insulated Electrical FR HR Insulated Wires
PVC Insulated Electrical FR HR Insulated Wires
Copper Single Multicore Flexible Cable
Copper Single Multicore Flexible Cable
AAC / AAAC / ACSR Conductors
AAC / AAAC / ACSR Conductors
LT Power Cables
LT Power Cables
LT/PC XLPE Power Control Cable
LT/PC XLPE Power Control Cable
Flat Travelling Cables
Flat Travelling Cables
Tsunami Cables
Tsunami Cables
Telecommunication Cables / Jelly Filled Cables
Telecommunication Cables / Jelly Filled Cables
Insulated Jelly Filled Cables
Insulated Jelly Filled Cables
33/11/1.1 KV Pin, Stain, Post And Disc Type Porcel
33/11/1.1 KV Pin, Stain, Post And Disc Type Porcel




Contact Details
K. M. CABLES & CONDUCTORS
No. 234, 3rd Floor, Garudachar Complex, (Above Hotel Vijay Vihar) Chickpet, Bangalore - 560053, Karnataka, India
Phone:91-80-22351170/71/22253445/22286169
Fax:91-80-22286457
Send Mail   Send SMS
Key Personnel
Mr. Rishi Kansal
Mobile:+919341285508

 
Translate In : View in English View in Spanish View in French View in German View in Italian View in Chinese (Simplified) View in Japanese View in Korean View in Arabic View in Portuguese
Copyright © 2011-12 by K. M. CABLES & CONDUCTORS All Rights Reserved.